Nicolet FT-IR spectrometers are the highest performance FT-IR systems available. Every facet has been engineered to facilitate sample handling, introduce options to scientists, and increase throughput in the laboratory. Because it is built on a common optical and electronics platform, it is easy to upgrade to the highest level of performance and application.
The Nicolet FT-IR Spectrometer Family Includes:
Superior optical throughput
Superior signal-to-noise ratio
High resolution
Multiple spectral ranges: mid-IR, near-IR, far-IR, and UV-Visible
Rapid scanning for fast kinetics
Smart Accessories
Infrared (IR) microscopy
FT-Raman
Hyphenated techniques: gas chromatography-IR (GC-IR), thermogravimetric analysis-IR (TGA-IR), and liquid chromatography-IR (LC-IR)
Smart Purge system
Nicolet FT-IR Smart System
Smart Systems automatically link the setup, testing, and operation of spectrometers, software, sampling accessories, and spectral information, leaving you free to focus on the experiment or analysis. Smart Systems recognize how you normally use the system and automatically set up the spectrometer for a particular experiment.
Smart Accessories
Nicolet FT-IR is compatible with all commercial accessories that fit into a standard sample compartment. However, the full power of a Smart System can be realized with Smart Accessories, which provide:
Quick and easy, snap-in installation
Automatic recognition and optimization
Permanent, pinned-in-place alignment
High throughput
High performance
Exceptionally efficient purge
Our portfolio includes a multitude of Smart Accessories designed to fit your every sampling need. Smart Accessories offer the following sampling techniques:
Transmission
Diamond ATR
Diffuse reflectance
Single-bounce ATR
Multiple-bounce ATR
Mid-IR fiber optics
Near-IR fiber optics
Corrosion-resistant ATR
Research-grade ATR
Research-grade diffuse reflectance
Near-IR diffuse reflectance
Micro ATR
Specular reflectance
Grazing angle reflectance
System Optics
The foundation of the Nicolet FT-IR spectrometer is its precision-cast baseplate. Its compact optical path minimizes beam pathlength and improves spectral performance by limiting the number of beam reflections. This opto-mechanical excellence means your results are extremely reproducible from scan to scan.
Precision-Cast Optics
Pinned-in-place
Compact optical path
Best reproducibility
Monolithic diamond-turned mirrors
Permanent alignment
Highest throughput
Five External Beam Options
Emission port
Right-side Passport
Left-side Passport
Front-facing external port
Front-facing external detector port
Sources
The high-intensity, long-lasting ETC EverGlo* mid-IR source is standard on the Nicolet FT-IR spectrometer. The source is even more efficient than watercooled sources, and delivers a significantly higher energy output. The computerized, dual-source option provides the greatest flexibility for multiple spectral ranges, allowing coverage from the UV-Visible to the far-IR. The computer-controlled aperture for Nicolet FT-IR spectrometers automatically sets the correct aperture size depending upon the resolution and spectral range selected. The 'Rest' mode extends the life of the source and users have the option of a 'Turbo' mode for further enhancements in throughput. The computer-controlled screen wheel provides convenient beam attenuation for highly sensitive detectors.
Computer-Controlled Dual Sources
ETC EverGlo* 9600 cm-1 to 20 cm-1
Whitelight 27000 cm-1 to 2000 cm-1
*Patent Pending
Detectors
We offer the widest variety of detectors designed and optimized to cover any spectral range or experimental configuration with the highest possible performance.
Features
Pinned-in-place
Easy interchange
Automatic detector recognition
Smart Systems recognize which detectors have been installed and where they are located. No switches, adjustments, or changes are required to the hardware or software for the detector to be active. The Monoflect dual detector system allows you to quickly switch between internally mounted detectors. New thermo-electrical designs enable faster cooling of detectors using less power, resulting in higher stability and faster response.
Beamsplitters
For mid-IR applications, we offer as standard configuration, either a mid-IR optimized Ge-on-KBr beamsplitter, or the proprietary XT-KBr beamsplitter, which can cover the region from 11000 cm-1 to 375 cm-1.
Features
Automatic recognition
Optimized spectral range
Instant alignment
Extra beamsplitters can be stored easily inside the purged and thermally equilibrated environment of the optical bench. A latched access door and the quick-release Talon beamsplitter-locking mechanism allow easy access to the beamsplitter without breaking instrument purge and preventing beamsplitter fogging.
Smart Purge System
The unique Smart Purge system available for the Nicolet FT-IR automatically detects when you have opened the spectrometer door. Smart Purge then automatically increases the flow of purge gas in your spectrometer to blast the sample compartment area free from unpurged lab air. Smart Purge automatically turns itself down when the spectrometer is ready to collect data, and provides the fastest possible purge recovery time in between successive samples to ensure that you are collecting data as quickly and efficiently as possible.
Vectra Interferometer
The Nicolet FT-IR spectrometer incorporates the highest performance interferometer available in the industry. The Vectra interferometer bearing rides on a cushion of air and has performance characteristics that are similar to a traditional air-bearing interferometer, with the added advantage of not requiring an external air supply. The standard resolution of the Nicolet 6700 spectrometer is 0.09 cm-1. In addition, the Vectra interferometer features dynamic alignment ensuring that it is constantly maintained at optimum performance. Dynamic alignment is the only mechanism that can actively compensate for all known modes of interferometer misalignment, including ambient temperature changes.
Software
OMNIC software for Nicolet FT-IR spectrometers provides a powerful Windowsฎ compatible interface for complete data collection and processing. Live data displays, active spectrometer diagnostics, and spectral quality checking assure the best possible data. Extensive data processing analysis and reporting tools allow you to make the most of your results. And it has the most extensive on-line help system currently available, which includes FT-IR theory and sample handling.
OMNIC Includes:
Data collection, manipulation, and processing packages
Preview data collection
Search of commercial libraries and the creation and management of user generated libraries with the Advanced Library Manager
QC Compare for raw materials quality control
Basic quantitative analysis tools
GLP-ready electronic Report Notebook
Spectral interpretation
Automated atmospheric correction
File conversion utilities, for older Thermo and other common file formats
Easy Identification
Standard software includes detailed spectral interpretation information on over 100 common functional groups
HTML format interpretation information can be included in reports and presentations
Excellent tool for training new users or reference for non-spectroscopists
Unparalleled collection of FT-IR databases for identification of unknown compounds
User library creation is a standard feature
|